Overall dimensions: 160x90x42 mm
Limits of permissible basic errors of the device when measuring AC RMS using a current converter (current meter): ±15% ±2 EMR in measuring range 0.02-2.00 A at AM signals with carrier frequencies 4545 Hz, 5000 Hz, 5555 Hz (TRC4)
Limits of permissible basic errors of the device when measuring AC RMS using a current converter (current meter): ±10% ±2 EMR in the measuring range of 0.02-2.00 A at FM signals with carrier frequencies 475 Hz, 525 Hz, 575 Hz, 625 Hz, 675 Hz, 725 Hz, 775 Hz, 825 Hz, 875 Hz, 925 Hz.
Limits of permissible basic errors of the device when measuring AC RMS using a current converter (current meter): ±10% ±2 EMR over a measurement range of 0.02-2.00 A at AM signals with carrier frequencies of 420 Hz, 480 Hz, 580 Hz, 720 Hz, 780 Hz (TRCZ)

Description

It is used for operative determination of causes of disturbance of normal operation of rail circuits (rail connectors of jumpers, wires) on the railway

Specifications

Overall dimensions
160x90x42 mm
Limits of permissible basic errors of the device when measuring AC RMS using a current converter (current meter)
±15% ±2 EMR in measuring range 0.02-2.00 A at AM signals with carrier frequencies 4545 Hz, 5000 Hz, 5555 Hz (TRC4)
Limits of permissible basic errors of the device when measuring AC RMS using a current converter (current meter)
±10% ±2 EMR in the measuring range of 0.02-2.00 A at FM signals with carrier frequencies 475 Hz, 525 Hz, 575 Hz, 625 Hz, 675 Hz, 725 Hz, 775 Hz, 825 Hz, 875 Hz, 925 Hz.
Limits of permissible basic errors of the device when measuring AC RMS using a current converter (current meter)
±10% ±2 EMR over a measurement range of 0.02-2.00 A at AM signals with carrier frequencies of 420 Hz, 480 Hz, 580 Hz, 720 Hz, 780 Hz (TRCZ)
Limits of permissible basic errors of the device when measuring AC RMS using a current converter (current meter)
±10% ±2 EMR in the measuring range of 0.02-20.0 A for ALS-EN signals with carrier frequency 174.38Hz
Limits of permissible basic errors of the device when measuring AC RMS using a current converter (current meter)
±10% ±2 EMR in the measuring range of 0.02-20.0 A for ALS-N signals with frequency 25Hz, 50Hz, 75Hz, measured without taking into account pauses between pulses
Limits of permissible basic errors of the device when measuring AC RMS using a current converter (current meter)
±12% ±2 EMR over the measuring range 20.0-200 A at continuous AC signals of 25Hz, 50Hz, 75Hz frequency
Limits of permissible basic errors of the device when measuring AC RMS using a current converter (current meter)
±10% ±2 EMR over a measuring range of 0.02-20.0 A at continuous AC signals of 25Hz, 50Hz, 75Hz
Tolerance limit of the basic error of the device when measuring AC RMS by superimposing it on the rail head of P65 type with ?
±10% ±2 EMR in the measuring range 0.02-2.00 A at AM signals with carrier frequencies 4545 Hz, 5000 Hz, 5555 Hz (TRC4)
Tolerance limit of the basic error of the device when measuring AC RMS by superimposing it on the rail head of P65 type with ?
±10% ±2 EMR in the measuring range of 0.02-2.00 A at FM signals with carrier frequencies 475 Hz, 525 Hz, 575 Hz, 625 Hz, 675 Hz, 725 Hz, 775 Hz, 825 Hz, 875 Hz, 925 Hz.
Tolerance limit of the basic error of the device when measuring AC RMS by superimposing it on the rail head of P65 type with ?
±10% ±2 EMR over a measurement range of 0.02-2.00 A at AM signals with carrier frequencies of 420 Hz, 480 Hz, 580 Hz, 720 Hz, 780 Hz (TRCZ)
Tolerance limit of the basic error of the device when measuring AC RMS by superimposing it on the rail head of P65 type with ?
±10% ±2 EMR in the measuring range of 0.02-20.0 A for ALS-EN signals with carrier frequency 174.38Hz
Tolerance limit of the basic error of the device when measuring AC RMS by superimposing it on the rail head of P65 type with ?
±10% ±2 EMR in the measuring range of 0.02-20.0 A for ALS-N signals with frequency 25Hz, 50Hz, 75Hz, measured without taking into account pauses between pulses
Tolerance limit of the basic error of the device when measuring AC RMS by superimposing it on the rail head of P65 type with ?
±10% ±2 EMR over a measuring range of 0.02-20.0 A at continuous AC signals of 25Hz, 50Hz, 75Hz
The device, when connected to the AC converter (current measuring clamps), provides the ability to
Measurements in rail jumpers, without breaking the electric circuit, of alternating current of sinusoidal form with frequency 25Hz, 50Hz, 75Hz in the range from 0,02 to 200A, at frequency 175Hz in the range from 0,02 to 20A, and at frequencies higher than
The device provides status indication
autonomous power supply (when the device is switched on), its charging process, selection frequency, input signal AC values, presence of input signal manipulation, value of permanent magnetic field induction and overload of input measuring devices
The device has the function of displaying spectrogram of signal levels of working frequencies in logarithmic scale of amplitude
0.02...20 ?
The device has the function of decoding ALSN-EN codes.
At the frequency 174.38 Hz with twofold fachoraznostnyh modulation in the form of modified Bauer code. In this case the decoded code in hexadecimal system of calculation on the first and second subchannels is displayed on the screen of the device, the numb
The device has the function of decoding and displaying the type of transmitter used.
KPT-5(8), KPT-7(9) and KPT-11
The device has a function of decoding and displaying codes
"?", "?" and "??" ALSN signals
The device has the function of rail magnetisation control by indication of permanent magnetic field induction on the rail surfac
In the range of ± 20 mT and resolution of 0.1 mT with measurement error ± 3 mT
The device has the function of measuring the duration of the first interval between the pulses of codes "Z" and "Zh" of ALSN sig
In the range from 60 ms to 240 ms with an error of ± 12 ms visit/shift
Operating frequencies of the device, bank 1 contains frequencies
5555 kg
Operating frequencies of the device, bank 2 contains frequencies
925 kg
The device has the function of measuring the duration of the first interval between the pulses of codes "Z" and "Zh" of ALSN sig
in the range from 60 ms to 240 ms with error ± 8 ms visit/shift
The device has the function of measuring the duration of the first interval between the pulses of codes "Z" and "Zh" of ALSN sig
In the range from 60 ms to 240 ms with error ±12 ms visit/shift
The device has the function of measuring the pause duration between the pulses of the code "KZh" at the signal frequency of 25,
60...1200 visit/shift
The instrument is powered by a lithium-polymer battery with rated voltage
3.7 thousand m³
Continuous operation time from a fully charged battery at ambient temperature from 0 to 40°C, not less than
B1/B8 2100/900 MHz kcal/h
Average lifetime of the device
8 kVAr
Average MTBF, not less than
30000 kcal/h
Weight of the device, not more
0.55 m² living area
Range of signalling currents in the rail line at input frequency 25, 50, 75 Hz
0.2...20
Range of signalling currents in the rail line at an input signal frequency of 175 Hz
0.02...20
Range of signalling currents in the rail line at input signal frequency 420, 480, 580, 720, 780, 4545, 5000, 5555 Hz
0.02...2
Range of signal currents in the rail line at input signal frequency 475, 525, 575, 625, 675, 725, 775, 825, 875, 925 Hz
0.02...2

Related Products

Current Indicator AП110Б-3811010

Current Indicator AП110Б-3811010

$3-$18 USD
Reading range, A.: 30-0-30
Applicability: Cars GAZ, MAZ, KamAZ
LLC "NKP "AUTOPRIBOR" 🇷🇺
Digital Current, Voltage, and Frequency Measuring Device SShP02.01P

Digital Current, Voltage, and Frequency Measuring Device SShP02.01P

$90-$300 USD
Overall dimensions, mm: 96×48×95
Overall dimensions, mm: 96×48×95
ELECTROPRIBOR OJSC 🇷🇺
Energy Metering and Communication Cabinets (ШСУ)

Energy Metering and Communication Cabinets (ШСУ)

$450-$1,800 USD
Degree of protection: IP54
Degree of protection: IP54
PROMSERVIS OJSC 🇷🇺
Multifunctional Measuring Devices ESM-ET

Multifunctional Measuring Devices ESM-ET

$150-$600 USD
Nominal values of phase (line) voltage: 57,7 (100); 230 (400); 400 (690)
Energoservis Engineering Center LLC 🇷🇺
Multifunctional Single-Phase Electric Energy Meter ROTEK RTM-01

Multifunctional Single-Phase Electric Energy Meter ROTEK RTM-01

$15-$48 USD
Number of tariffs: 4
Average MTBF: 250000
NTC ROTEK LLC 🇷🇺
Universal Voltmeter V7-81 for AC/DC Voltage Measurement

Universal Voltmeter V7-81 for AC/DC Voltage Measurement

$420-$1,800 USD
DC voltage: 0...1000
Input signal frequency: 10...1000000
TECHNOYAKS OJSC 🇷🇺
Digital Panel Voltmeter V00 for AC/DC Voltage Measurement

Digital Panel Voltmeter V00 for AC/DC Voltage Measurement

$9-$36 USD
Overall dimension, mm: 40×40×44
Overall dimension, mm: 40×40×44
ELECTROPRIBOR OJSC 🇷🇺
Static Single-Phase Electric Energy Meter FOСHOS 1 230V 5(100)A IQOLSM(1)-C 4G(LTE)

Static Single-Phase Electric Energy Meter FOСHOS 1 230V 5(100)A IQOLSM(1)-C 4G(LTE)

$90-$300 USD
Maximum current: 100
Nominal voltage: 230
TELEMATIC SOLUTIONS LLC 🇷🇺
Three-Phase Active and Reactive Power Measuring Converter E1849

Three-Phase Active and Reactive Power Measuring Converter E1849

$15-$48 USD
Mounting: possibility of mounting on t-rail tn-35-7;5 according to iec 60715-2013 or directly on the panel
Mounting: possibility of mounting on t-rail tn-35-7;5 according to iec 60715-2013 or directly on the panel
ALEKTO-ELECTRONICS LLC 🇷🇺
Air Speed Anemometer TKA-PKM(50)

Air Speed Anemometer TKA-PKM(50)

$150-$480 USD
Number of elements in the chain: 1
Chain sizes depending on the number of elements: 205
NTP "TKA" LLC 🇷🇺
Multifunction Digital Electrical Measurement Device Model SHM96

Multifunction Digital Electrical Measurement Device Model SHM96

$150-$540 USD
Basic error: Current and voltage: ± 0.2 %; power: ± 0.5 %; frequency: ± 0.01 Hz; analogue output: ± 0.5 %
Basic error: Current and voltage: ± 0.2 %; power: ± 0.5 %; frequency: ± 0.01 Hz; analogue output: ± 0.5 %
ELECTROPRIBOR OJSC 🇷🇺
Multifunctional Electric Energy Meters - Model XYZ123

Multifunctional Electric Energy Meters - Model XYZ123

$150-$540 USD
Type of product according to PP RF 616: Instruments and other instruments for measurement, control and testing
Type of product according to PP RF 616: Instruments and other instruments for measurement, control and testing
TAIPIT-IP LLC 🇷🇺
Digital Panel Measuring Device for DC Current/Voltage - Model Щ23.4

Digital Panel Measuring Device for DC Current/Voltage - Model Щ23.4

$90-$300 USD
Overall dimensions, mm: 96×96×86
Overall dimensions, mm: 96×96×86
ELECTROPRIBOR OJSC 🇷🇺
Multifunctional Measuring Converter ENIP-2 Modification 04

Multifunctional Measuring Converter ENIP-2 Modification 04

$300-$1,800 USD
Measurement range of AC current, % of Inom: 1...200
Voltage measurement range, % of Unom: 5...150
Energoservis Engineering Center LLC 🇷🇺
Multifunctional Single-Phase Energy Meter "MIRTEK-12-RU", W6 Case

Multifunctional Single-Phase Energy Meter "MIRTEK-12-RU", W6 Case

$15-$60 USD
Accuracy class of active energy: 1,0
Accuracy class of active energy: 1,0
MIRTEK LLC 🇷🇺
AC Voltmeter V3-71 for Accurate Measurements

AC Voltmeter V3-71 for Accurate Measurements

$90-$300 USD
Minimum range: 0.0001
Maximum range: 300
RIP-Impuls LLC 🇷🇺
Portable Electronic Level Meter INSOL 907

Portable Electronic Level Meter INSOL 907

$900-$3,000 USD
Level measurement range: 0.004...15
Temperature measurement range: -40...90
INSOL LLC 🇷🇺
Lux Meter "TKA-LUX" for Measuring Light Intensity

Lux Meter "TKA-LUX" for Measuring Light Intensity

$90-$300 USD
Illuminance measurement range: 1...200000
Limits of permissible basic relative error of illuminance measurement: 6
NTP "TKA" LLC 🇷🇺
Multifunctional Standard Electric Measuring Device "Energomonitor-3.1KM" Model Energomonitor-3.1KM-C-000

Multifunctional Standard Electric Measuring Device "Energomonitor-3.1KM" Model Energomonitor-3.1KM-C-000

$1,500-$6,000 USD
Display: Available
Display: Available
MARS-ENERGO LLC 🇷🇺
Multifunctional Meter for Light, Humidity, and UV Measurement TKA-PKM (65)

Multifunctional Meter for Light, Humidity, and UV Measurement TKA-PKM (65)

$420-$1,500 USD
Number of elements in the chain: 1
Chain sizes depending on the number of elements: 160
NTP "TKA" LLC 🇷🇺
Request via WhatsApp