1
Request Details
2
Contact Info

What do you need?

Describe the product or service you are looking for

Your Contact Information

We will contact you as soon as possible

Request Submitted!

Thank you! We will contact you soon with the best offers.

Measurement Converter E849EL for Active and Reactive Power

Measurement Converter E849EL for Active and Reactive Power

Brand: ELEKTROPRIBOR
$1,800 - $7,200 USD
MOQ: 1 pieces

Key Features

Overall dimensions, mm: 108×91×57; 162×91×61 (version "L")
Ethernet communication interface: Quantity: 0, 1, 2; 100BASE-TX; protocols: IEC 61850-8-1 (MMS), IEC 60870-5-104 (with timestamp), Modbus TCP (Note: Only one Ethernet interface supports IEC 61850-8-1 (MMS)).
Measurement of single-phase and three-phase network parameters: Active power, reactive power, total power, power factor, mains frequency.
Mounting: DIN rail 35 mm

More from ELEKTROPRIBOR

MI80.3 Indication Modules for Measurement Display

MI80.3 Indication Modules for Measurement Display

$90-$300
Digital Display Module MI120.3 for Measurement Indicators

Digital Display Module MI120.3 for Measurement Indicators

$90-$300
Three-Channel AC Current and Voltage Measuring Converter E3854EL

Three-Channel AC Current and Voltage Measuring Converter E3854EL

$90-$300
AC Current and Voltage Measuring Converter E1854EL

AC Current and Voltage Measuring Converter E1854EL

$90-$300
Digital Indication Module MI120.1

Digital Indication Module MI120.1

$90-$300
Digital Microammeter, Milliammeter, Ammeter, and Voltmeter E42700.8

Digital Microammeter, Milliammeter, Ammeter, and Voltmeter E42700.8

$9-$36
Digital Panel Meter for Current, Voltage, and Frequency Measurement - Model SHP02

Digital Panel Meter for Current, Voltage, and Frequency Measurement - Model SHP02

$90-$300
T44 Digital Information Display for Electric and Physical Measurements

T44 Digital Information Display for Electric and Physical Measurements

$150-$540
Digital Panel Meter for Current, Voltage, and Frequency Measurement - Model ЩП72

Digital Panel Meter for Current, Voltage, and Frequency Measurement - Model ЩП72

$90-$360
Electronic LED Clock Display TCH74

Electronic LED Clock Display TCH74

$180-$720
Digital Information Display T54 for Electrical Measurements

Digital Information Display T54 for Electrical Measurements

$90-$360
AC Frequency Measurement Converter E1858EL

AC Frequency Measurement Converter E1858EL

$90-$300
Analog Voltmeter M42496 for DC and Pulsating Current 0-250V

Analog Voltmeter M42496 for DC and Pulsating Current 0-250V

$9-$36
MI120.2 Indication Modules for Measurement Display

MI120.2 Indication Modules for Measurement Display

$90-$300
DC and AC Voltage and Current Measurement Converter E856EL

DC and AC Voltage and Current Measurement Converter E856EL

$90-$360
Digital Microamperemeter, Milliampere Meter, Ammeter, and Voltmeter E42704

Digital Microamperemeter, Milliampere Meter, Ammeter, and Voltmeter E42704

$9-$36
DC Current and Voltage Measurement Converter for Electrical Systems E1856EL

DC Current and Voltage Measurement Converter for Electrical Systems E1856EL

$90-$300
Measurement Converter for AC Electrical Parameters E900EL

Measurement Converter for AC Electrical Parameters E900EL

$150-$540
Panel Meter for Measuring Voltage with Angular Mechanism Model C42703

Panel Meter for Measuring Voltage with Angular Mechanism Model C42703

$9-$36
Digital Panel Meter for Measuring Current and Voltage in DC Networks - Model Щ120

Digital Panel Meter for Measuring Current and Voltage in DC Networks - Model Щ120

$90-$360

Description

E849EL converters are designed to measure and convert active and/or reactive power in single-phase and three-phase 3- and 4-wire AC power networks into unified DC output signals and a sequence of digital signals for transmission via RS485 interfaces (IEC 60870-5-101 protocols with time stamp, Modbus RTU), Ethernet (protocols IEC 61850-8-1 (MMS), IEC 60870-5-104 with time stamp, Modbus TCP).
Converters can be used for: active, reactive and active/reactive power control; measurement of active and reactive energy (given/received, with accumulation);
monitoring and control of power quality.
The converter supports the IEC 61850-8-1 digital substation protocol (MMS). E849EL is included in the State Register of SI of the Russian Federation No. 66759-17. Inter-test interval: without LCD - 11 years; with LCD - 8 years.

Specifications

Overall dimensions, mm
108×91×57; 162×91×61 (version "L")
Ethernet communication interface
Quantity: 0, 1, 2; 100BASE-TX; protocols: IEC 61850-8-1 (MMS), IEC 60870-5-104 (with timestamp), Modbus TCP (Note: Only one Ethernet interface supports IEC 61850-8-1 (MMS)).
Measurement of single-phase and three-phase network parameters
Active power, reactive power, total power, power factor, mains frequency.
Mounting
DIN rail 35 mm
Performances
General industrial; for operation at NPP (safety class 4 according to NP-001-2015); for operation at sea vessels (OM2)
Inspection interval
11 years (with LCD display - 8 years)
Warranty period of operation
24 mos.
Average service life, at least
20 years (with LCD display - 15 years)
Average MTBF
250000 h (with LCD - 150000 h)
Bluetooth (for converters of "L" version (overall size 162×91×61 mm))
Quantity: 0, 1; Bluetooth 4.0 (connection with devices with interface version not lower than 2.1+ EDR class 2 (SPP profile available); line of sight distance - not more than 10 metres).
GPS/GLONASS synchronisation module (for transmitters of "L" version (overall size 162×91×61 mm))
Built-in GPS/GLONASS receiver (antenna and cable are not included); Connector type - SMA-M; Synchronisation accuracy - not more than 0.1 ms.
Temperature sensor (for transmitters of version "L" (overall size 162×91×61 mm))
Type DS18B20 (included in the delivery set); cable length - 3 m; ambient temperature measurement: from -50 °C to +70 °C; transmission via interfaces to external devices and display on LCD (if available)
Weight, kg, not more
0,6
Measurement of active and reactive energy
Active energy of forward and reverse direction; Reactive energy of forward and reverse direction
Measurement of power quality parameters
Duration and depth of voltage dip; duration of voltage interruption; duration of temporary overvoltage; frequency deviation
Display of information
LCD, colour LCD, 46.7x35.4 mm (2.2''), single LED indicators
Input signals
1 A; 5 A (0.02 to 2.0-Inom); (phase/line): 57.7/100 V, 220/380 V, 230/400 V (0.02 to 1.2-Unom); 45 to 55 Hz
Measurement time
0.1 sec.
Basic error
By power: ± 0,5 %; by frequency: ± 0,01 Hz; by analogue output: ± 0,5 %
Galvanic isolation of input and output circuits, power supply circuits, interfaces
Got it
RS485 communication interface
Quantity: 1, 2; Protocols: IEC 60870-5-101 (with time stamp), Modbus RTU
Analog output
Quantity: 0, 1, 2, 3; reprogrammable ranges: 0...5 mA, 4...20 mA, 0...20 mA, 0...2.5...5 mA, 4...12...20 mA, -5...0...+5 mA, 0...10...20 mA
Time synchronization
Ethernet (SNTP protocols, IEC60870-5-104 with time stamp), RS485 (IEC 60870-5-101 with time stamp); counting accuracy not more than 10 ms; in the absence of synchronisation not more than 0.3 sec./day.
Event logs
Log of switching on/off the device; Log of electric energy quality indicators; Event log of measured parameters; Event log of discrete inputs and relay outputs (up to 280 events with automatic overwriting of earlier events at up to 1511841:Log of measureme
Storage of measurement results
On PC to log file with .csv extension using "Configurator" software
Discrete inputs
Quantity: 0, 8. Voltage 24 V, current 10 mA, "dry contact". Voltage 220 V, resistance of one discrete input - at least 0,8 Mohm, "wet contact" (requires an external source of DC 220 V) - for gab. size 162×91×61 mm. For
Discrete relay outputs
Quantity: 0, 1, 2, 3, 4; NC contact with parameters ~250 V, =30 V, 5 A Note: For inverters with special version "L" (overall size 162×91×61 mm) there is no version with 4 digital outputs.
Power supply voltage
24VH - (24+12/-6) VDC; 220VU - 85 to 305 VAC, frequency (50 ± 0.5) Hz or 110 to 430 VDC; measuring circuit - 85 to 305 VAC, frequency (50 ± 0.5) Hz
Consumption power, not more
Power supply circuit at rated input signals: 8 V-A; for series circuit: 0.1 V-A; for parallel circuit: 0.05 V-A
Reprogramming
Via "Configurator" software (RS485, Ethernet interface); via web-interface (Ethernet interface); via buttons on the front panel (if LCD display is available).
Operating temperature range
Without LCD display: -40 to +70 °C (relative humidity 98 % at +35 °C); with LCD display: -20 to +70 °C (relative humidity 90 % at +30 °C); with "Sea Register" acceptance: -40 to +55 °C (relative humidity 90 % at +25 °C)
Degree of protection
IP30 according to GOST 14254-2015
Electromagnetic compatibility
GOST R IEC 61326-1-2014 for class A
Interference immunity
GOST R IEC 61326-1-2014 for class A
Industrial noise level
GOST 30805.22-2013 for Class A
Resistance to mechanical influences
Group N1 according to GOST R 52931-2008; for devices with "Marine Register" acceptance in accordance with the requirements of RM RS (Annex 13, 14 p.10, part IV of Pr. RS/TN).

Related Products

Three-Phase Active and Reactive Power Measuring Converter E1849

Three-Phase Active and Reactive Power Measuring Converter E1849

$15-$48 USD
Mounting: possibility of mounting on t-rail tn-35-7;5 according to iec 60715-2013 or directly on the panel
Mounting: possibility of mounting on t-rail tn-35-7;5 according to iec 60715-2013 or directly on the panel
ALEKTO-ELECTRONICS LLC 🇷🇺
Three-Phase Active Power Measurement Converter E1859

Three-Phase Active Power Measurement Converter E1859

$15-$48 USD
Mounting: possibility of mounting on t-rail tn-35-7;5 according to iec 60715-2013 or directly on the panel
Mounting: possibility of mounting on t-rail tn-35-7;5 according to iec 60715-2013 or directly on the panel
ALEKTO-ELECTRONICS LLC 🇷🇺
Energy Metering and Communication Cabinets (ШСУ)

Energy Metering and Communication Cabinets (ШСУ)

$450-$1,800 USD
Degree of protection: IP54
Degree of protection: IP54
PROMSERVIS OJSC 🇷🇺
Multifunctional Measuring Devices ESM-ET

Multifunctional Measuring Devices ESM-ET

$150-$600 USD
Nominal values of phase (line) voltage: 57,7 (100); 230 (400); 400 (690)
Energoservis Engineering Center LLC 🇷🇺
Multifunctional Single-Phase Electric Energy Meter ROTEK RTM-01

Multifunctional Single-Phase Electric Energy Meter ROTEK RTM-01

$15-$48 USD
Number of tariffs: 4
Average MTBF: 250000
NTC ROTEK LLC 🇷🇺
Universal Voltmeter V7-81 for AC/DC Voltage Measurement

Universal Voltmeter V7-81 for AC/DC Voltage Measurement

$420-$1,800 USD
DC voltage: 0...1000
Input signal frequency: 10...1000000
TECHNOYAKS OJSC 🇷🇺
Digital Panel Voltmeter V00 for AC/DC Voltage Measurement

Digital Panel Voltmeter V00 for AC/DC Voltage Measurement

$9-$36 USD
Overall dimension, mm: 40×40×44
Overall dimension, mm: 40×40×44
ELECTROPRIBOR OJSC 🇷🇺
Static Single-Phase Electric Energy Meter FOСHOS 1 230V 5(100)A IQOLSM(1)-C 4G(LTE)

Static Single-Phase Electric Energy Meter FOСHOS 1 230V 5(100)A IQOLSM(1)-C 4G(LTE)

$90-$300 USD
Maximum current: 100
Nominal voltage: 230
TELEMATIC SOLUTIONS LLC 🇷🇺
Air Speed Anemometer TKA-PKM(50)

Air Speed Anemometer TKA-PKM(50)

$150-$480 USD
Number of elements in the chain: 1
Chain sizes depending on the number of elements: 205
NTP "TKA" LLC 🇷🇺
Multifunction Digital Electrical Measurement Device Model SHM96

Multifunction Digital Electrical Measurement Device Model SHM96

$150-$540 USD
Basic error: Current and voltage: ± 0.2 %; power: ± 0.5 %; frequency: ± 0.01 Hz; analogue output: ± 0.5 %
Basic error: Current and voltage: ± 0.2 %; power: ± 0.5 %; frequency: ± 0.01 Hz; analogue output: ± 0.5 %
ELECTROPRIBOR OJSC 🇷🇺
Multifunctional Electric Energy Meters - Model XYZ123

Multifunctional Electric Energy Meters - Model XYZ123

$150-$540 USD
Type of product according to PP RF 616: Instruments and other instruments for measurement, control and testing
Type of product according to PP RF 616: Instruments and other instruments for measurement, control and testing
TAIPIT-IP LLC 🇷🇺
Digital Panel Measuring Device for DC Current/Voltage - Model Щ23.4

Digital Panel Measuring Device for DC Current/Voltage - Model Щ23.4

$90-$300 USD
Overall dimensions, mm: 96×96×86
Overall dimensions, mm: 96×96×86
ELECTROPRIBOR OJSC 🇷🇺
Multifunctional Measuring Converter ENIP-2 Modification 04

Multifunctional Measuring Converter ENIP-2 Modification 04

$300-$1,800 USD
Measurement range of AC current, % of Inom: 1...200
Voltage measurement range, % of Unom: 5...150
Energoservis Engineering Center LLC 🇷🇺
Multifunctional Single-Phase Energy Meter "MIRTEK-12-RU", W6 Case

Multifunctional Single-Phase Energy Meter "MIRTEK-12-RU", W6 Case

$15-$60 USD
Accuracy class of active energy: 1,0
Accuracy class of active energy: 1,0
MIRTEK LLC 🇷🇺
AC Voltmeter V3-71 for Accurate Measurements

AC Voltmeter V3-71 for Accurate Measurements

$90-$300 USD
Minimum range: 0.0001
Maximum range: 300
RIP-Impuls LLC 🇷🇺
Portable Electronic Level Meter INSOL 907

Portable Electronic Level Meter INSOL 907

$900-$3,000 USD
Level measurement range: 0.004...15
Temperature measurement range: -40...90
INSOL LLC 🇷🇺
Lux Meter "TKA-LUX" for Measuring Light Intensity

Lux Meter "TKA-LUX" for Measuring Light Intensity

$90-$300 USD
Illuminance measurement range: 1...200000
Limits of permissible basic relative error of illuminance measurement: 6
NTP "TKA" LLC 🇷🇺
Multifunctional Standard Electric Measuring Device "Energomonitor-3.1KM" Model Energomonitor-3.1KM-C-000

Multifunctional Standard Electric Measuring Device "Energomonitor-3.1KM" Model Energomonitor-3.1KM-C-000

$1,500-$6,000 USD
Display: Available
Display: Available
MARS-ENERGO LLC 🇷🇺
Multifunctional Meter for Light, Humidity, and UV Measurement TKA-PKM (65)

Multifunctional Meter for Light, Humidity, and UV Measurement TKA-PKM (65)

$420-$1,500 USD
Number of elements in the chain: 1
Chain sizes depending on the number of elements: 160
NTP "TKA" LLC 🇷🇺
Lux Meter for Measuring Illuminance - TKA-PKM (05)

Lux Meter for Measuring Illuminance - TKA-PKM (05)

$90-$300 USD
Number of elements in the chain: 1
Chain sizes depending on the number of elements: 31
NTP "TKA" LLC 🇷🇺
Request via WhatsApp